EDI ultrapure water purification system for laboratories
| SKU | Pack size | Availability | Price |
|---|---|---|---|
| V-Pure E50 | Máy | Backorder | 97,200,000VND |
Máy lọc nước siêu sạch EDI dùng cho phòng thí nghiệm is a laboratory instrument in the Pure Water Systems group from VPure™ (Vietnam). Specification: grade Type I, pack size Máy. Đáp ứng tiêu chuẩn ASTM D1193, ISO 3696, ASTM 1193-6. It is commonly used for laboratory operation, testing and production quality control. QEMIX supplies genuine Máy lọc nước siêu sạch EDI dùng cho phòng thí nghiệm with full documentation, Quick Quote and nationwide delivery in Vietnam. Contact us for partner pricing and technical support.
| Origin | Vietnam |
| Output water type | Type I (ultrapure water) |
| Filtration technology | RO combined with EDI electrodeionisation |
| Feed water | Tap water |
| Feed water conductivity | < 500 µS/cm |
| Feed water TDS | < 300 ppm |
| Feed water pressure | ≥ 2 bar (30 psi) |
| Output water standard | Meets ASTM D1193 Type I, ISO 3696, ASTM D1193-6 |
| Applications | AAS, HPLC, GC, GC-MS, LC-MS, life science and other analytical applications |
| Maximum flow rate | 2 litres/minute |
| Maximum capacity | 50 litres/hour |
| Output water conductivity | 0.055 µS/cm (25°C) |
| TOC | ≤ 5 ppb (µg/L) |
| Particle count | < 1 particle/mL |
| Display | Colour touch screen |
| Displayed parameters | Feed water conductivity (Q1), output water conductivity (Q2), cartridge status, consumable replacement timing and operating parameters |
| Power supply | 210–240 VAC, 50–60 Hz |
| Dimensions (D × W × H) | 500 × 460 × 500 mm |
The system is supplied with every component required for installation and operation, including:
- 01 main unit.
- 01 EDI deionisation module, pre-installed in the unit.
- 01 Ultrapure DI column set, pre-installed in the unit.
- 01 Ultrafilter (UF) column, pre-installed in the unit.
- 01 Type III water tap for the glassware washing sink.
- 01 separate RO pre-treatment unit for the feed water (dimensions: 420 × 370 × 185 mm).
- 02 sets of pre-filter cartridges comprising PP, Cation and CTO.
Consumables
To keep the output water within specification and the system running reliably, consumables should be replaced periodically as recommended below:
- Pre-filter set (PP, Cation, CTO): replace after 3–6 months.
- DI pre-treatment column: replace after 6–12 months.
- RO1 600G membrane: replace after 6–12 months.
- RO2 400G membrane: replace after 12–16 months.
- Ultrapure DI column set: replace after 12–16 months.
Note: replacement intervals may vary with feed water quality and how often the system is used.